Flicker: No Visible Flicker or Stroboscopic Effects
Indoor
Industrial/ Demanding Environments
Outdoor
- No visible or perceivable flicker over dimming range
- No stroboscopic effect when filming (camera)
- Complies with IEEE Standard P1789-2015 (IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers), in typical operating conditions at representative dimming levels.
- Addresses requirements of: California Title 24
- Complies with NEMA 77 standard at all dimming levels (ANSI C82.18 - 2022)
- Complies with NEMA 77 standard at all dimming levels (ANSI C82.18 - 2022)
-
Dimming : Range and Quality Equivalent to Incandescent Dimming
Indoor
Industrial/ Demanding Environments
Outdoor
- Dimming range from 100 to 0.1% or from 100 to 1% or from 100 to 5%
- Complies with: NEMA - ANSI C137.1-2022; ESTA E1.3 (Analog 0-10V), ANSI E1.11-2008 (R2018), ESTA DMX 512, USITT
- Addresses requirements of: California Title 24, ENERGY STAR®
- Dimming range from 100 to 10%
- Spec: Complies with: NEMA - ANSI C137.1-2022; ESTA E1.3 (Analog 0-10V)
- Dimming range from 100 to 10%
- Spec: Complies with: NEMA - ANSI C137.1-2022; ESTA E1.3 (0-10V Analog Control)
-
Controls Interface Supported: A Choice of Control Protocols to Cover Any Lighting Controls and Network Needs
Indoor
Industrial/ Demanding Environments
Outdoor
- Supports analog 0-10V OR D4i OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices
- Supports analog 0-10V OR D4i OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices.
- Supports analog 0-10V OR D4i OR Cell Connect OR DMX OR nLight OR SensorSwitch
- Programmable auxiliary outputs compatible with wide range of sensors and wired or wireless controls devices.
-
Dynamic Lighting - Tunable and Color: Ability to Adjust Color Temperature Over Customized Range. Smooth Transitions Between Intensity Levels and Color. Color Consistency in the Space
Indoor
Industrial/ Demanding Environments
Outdoor
- Supports Tunable White with DALI-2 OR DMX OR nLight
- Supports architainment RGBx with DMX
- Ability to adjust color temperature over customized range.
- Provides smooth transitions between intensity levels and color.
- Provides color consistency in the space
- Not Applicable
- Supports RGBx and RGBW with DMX
-
Consistent Behavior at Start Up/Shut Down: All Luminaires within a Space to have the Same Behavior at On and Off
Indoor
Industrial/ Demanding Environments
Outdoor
- No perceived timing difference at turn on, turn off and over dimming range
- Addresses requirements of California Title 24
- No perceived timing difference at turn on, turn off and over dimming range
- No perceived timing difference at turn on, turn off and over dimming range
-
No Electromagnetic Interference: No Unwanted Radiated or Conducted Interference in the Space
Indoor
Industrial/ Demanding Environments
Outdoor
- Complies with FCC title 47 part 15 class A & B
- Complies with FCC title 47 part 15 class A
- Complies with FCC title 47 part 15 class A
-
Surge & EFT Protection: Guard Against Failure
Indoor
Industrial/ Demanding Environments
Outdoor
- 2.5kV common and differential mode surge protection for indoor applications, complies with ANSI C62.41 Test Severity III - Cat A (ANSI C82.77-5-2017 Surge and Transient Standard)
- 6kV common and differential mode surge protection for industrial applications, complies with ANSI C62.41 Test Severity III - Cat B (ANSI C82.77-5-2017 Surge and Transient Standard)
- 6kV common and differential mode surge protection for outdoor applications, complies with ANSI C62.41 Test Severity III - Cat B (ANSI C82.77-5-2017 Surge and Transient Standard)
-
Additional Features
Indoor
Industrial/ Demanding Environments
Outdoor
- Configurable Thermal Protection for added safeguard based on known operating condition and luminaire design
- Ingress Protection: IP20 rated driver enclosure
- Standby power < 0.5W - Low power consumption as luminaire is set to (electronic) off
- Environmental standards: complies with RoHS3, REACH Art 33, Living Building Challenge™ Red List exemption
- Configurable Thermal Protection for added safeguard based on known operating condition and luminaire design
- Ingress protection: IP66 rated driver enclosure
- Standby power < 1W - Low power consumption as luminaire is set to (electronic) off
- Environmental standards: complies with RoHS3, REACH Art 33, Living Building Challenge™ Red List exemption
- Configurable Thermal Protection for added safeguard based on known operating condition and luminaire design
- Ingress protection: IP66 rated driver enclosure
- Standby power < 1W - Low power consumption as luminaire is set to (electronic) off
- Environmental standards: complies with RoHS3, REACH Art 33, Living Building Challenge™ Red List exemption